The AutoSmart processes the mV signal from any IRt/c or Micro IRt/c model, linearizes the signal and gives an analog output (4-20mA, 0-5V, 0-10V). No Impedance, leakage current, or linearity problems to worry about You can chose your range: 0-100C or 0-2050C target temperature. Custom calibrations are offered.
Accuracy holds with changes in ambient from -45 to 100 °C, with no drifting. IR Sensor heads from 1:2 to 10:1 optics, straight and side view mounting, built in air purge (cool to 120 °C), air purge jackets (cool to 175 °C), are available. Any precalibrated IRt/c or Micro IRt/c model from our product portfolio can be combined with the AutoSmart for linearized 4-20mA, 0-5V or 0-10V output.
Product Overview
The AutoSmart features:
• Input 12-24VDC
• Output 0-5V, 0-10V, 4-20mA
• 0-100°C or 0-250°C target temperature
• Non-contact
• Repeatability error 0.1% full scale
• Interchangeability ±1.5% full scale
• Resolution approx. 0.1°C
• Small size sensor
For more information - please contact us
Sensor Range: -35 to 250°C (-31 to 482°F)
Field of View: 17° (3:1) approximately
Minimum Spot Size: 5mm (0.2")
Output 0-5V, 0-10V, 4-20mA
Non-contact
Repeatability error 0,1% full scale
Interchangeability ±1,5% full scale
Resolution approx. 0,1°C (0.2°F)
Small size sensor
Sensor Range: -35 to 250°C (-31 to 482°F)
Field of View: 60° (1:1) approximately
Minimum Spot Size: 8mm (0.3")
Sensor Range: -35 to 250°C (-31 to 482°F)
Field of View: 3:1 (17°) approximately
Minimum Spot Size: 6mm (0.25")
Sensor Range: -35 to 250°C (-31 to 482°F)
Field of View: 110° (1:2) approximately
Minimum Spot Size: 3mm (0.1")
Sensor Range: -35 to 250°C (-31 to 482°F)
Field of View: 60° (1:1) approximately
Minimum Spot Size: 8mm (0.3")
Sensor Range: -35 to 250°C (-31 to 482°F)
Field of View: 60° (1:1) approximately
Minimum Spot Size: 8mm (0.3")
Sensor Range: -35 to 250°C (-31 to 482°F)
Field of View: 60° (1:1) approximately
Minimum Spot Size: 8mm (0.3")
Sensor Range: -35 to 250°C (-31 to 482°F)
Field of View: 110° (1:2) approximately
Minimum Spot Size: 3mm (0.1")
Sensor Range: 50 to 250°C (122 to 482°F)
Field of View: 14° (4:1) approximately
Minimum Spot Size: 3mm (0.1")
Sensor Range: 50 to 250°C (122 to 482°F)
Field of View: 14° (4:1) approximately
Minimum Spot Size: 3mm (0.1")
Sensor Range: -10 to 50°C (14 to 122°F)
Field of View: 110° (1:2) approximately
Minimum Spot Size: 3mm (0.1")
Sensor Range: -35 to 250°C (-31 to 482°F)
Field of View: 6° (10:1) approximately
Minimum Spot Size: 20mm (0.8")
Sensor Range: -35 to 250°C (-31 to 482°F)
Field of View: 11° (5:1) approximately
Minimum Spot Size: 20mm (0.8")