tech Notes

Technote #04 IRt/c controls paint curing with radiant heaters

A rather logical combination of heating method and

pending on the field-of-view required to see past the

control is radiant heat with an IRt/c for control.

elements to the painted surface. Test the location

They work extraordinarily well together, since both

by turning on the heater with no target present. The

the heating and measuring occur right at the sur-

change in reading should be small. Care should be

face, where the paint is located. The IRt/c reading

taken in mounting the IRt/c in such a way as to keep

is unaffected by reflections from the heater, since

its temperature below 93°C (200°F) and to keep the

the spectral response of the 6-14 micron IRt/c lens

lens clean. The IRt/c.3x, .5, and .10 are the preferred

filters out the shorter wavelengths of the radiant

models for this application because of their built-in

heater energy.

air purge. They can be used in environments with

Quick installation guide

temperatures up to 121°C (250°F) or higher when the

The IRt/c may be mounted in the shroud or reflector

air purge system is used. The narrow fields-of-view

of the radiant heater, such that it can see through

the elements. Select any of the IRt/c models, de-

pre-calibrted models

allow more leeway in positioning, and thus more

flexibility in installation.